Rebar Locator Model GW50 (+)
Specification: Bar diameter application range (mm): F 6-50. Maximum permissible error of Bar diameter: < + 1. Cover thickness measuring range: The first measuring range(mm): 6-90, The second measuring range (mm): 7-180. The maximum error of cover thickness: The first measuring range (mm): 6-59 < + 1, 60-69 < + 2, 70-90 < + 4. The second measuring range (mm): 7-79 < + 1, 80-119 < + 2, 120-180 < + 4.
Product Usage: Testing concrete cover thickness. Test concrete member internal reinforcement position, rebar spacing, reinforcement position distribution. Estimation bar diameter. Detection of Cable and Plumbing pipe.
Features: Investigation depth could reach 180mm. Single comprehensive probe. No need to replace during test. Back-lit screen lets instrument can be normal used under the condition of insufficient light. Machine software is complete. The report could be printed automatically connecting with computer. Grid scan of the rebar position. Profile scan of the rebar position.
Work Environment Condition: No strong alternating electromagnetic field. No corrosive gas in the air. Avoid larger vibration and impact. Avoid the LCD Panel contact with sunlight directly.
Specification: Bar diameter application range (mm): F 6-50. Maximum permissible error of Bar diameter: < + 1. Cover thickness measuring range: The first measuring range(mm): 6-90, The second measuring range (mm): 7-180. The maximum error of cover thickness: The first measuring range (mm): 6-59 < + 1, 60-69 < + 2, 70-90 < + 4. The second measuring range (mm): 7-79 < + 1, 80-119 < + 2, 120-180 < + 4.
Product Usage: Testing concrete cover thickness. Test concrete member internal reinforcement position, rebar spacing, reinforcement position distribution. Estimation bar diameter. Detection of Cable and Plumbing pipe.
Features: Investigation depth could reach 180mm. Single comprehensive probe. No need to replace during test. Back-lit screen lets instrument can be normal used under the condition of insufficient light. Machine software is complete. The report could be printed automatically connecting with computer. Grid scan of the rebar position. Profile scan of the rebar position.
Work Environment Condition: No strong alternating electromagnetic field. No corrosive gas in the air. Avoid larger vibration and impact. Avoid the LCD Panel contact with sunlight directly.
Description
About
Description
About
Rebar Locator Model GW50 (+)
Specification: Bar diameter application range (mm): F 6-50. Maximum permissible error of Bar diameter: < + 1. Cover thickness measuring range: The first measuring range(mm): 6-90, The second measuring range (mm): 7-180. The maximum error of cover thickness: The first measuring range (mm): 6-59 < + 1, 60-69 < + 2, 70-90 < + 4. The second measuring range (mm): 7-79 < + 1, 80-119 < + 2, 120-180 < + 4.
Product Usage: Testing concrete cover thickness. Test concrete member internal reinforcement position, rebar spacing, reinforcement position distribution. Estimation bar diameter. Detection of Cable and Plumbing pipe.
Features: Investigation depth could reach 180mm. Single comprehensive probe. No need to replace during test. Back-lit screen lets instrument can be normal used under the condition of insufficient light. Machine software is complete. The report could be printed automatically connecting with computer. Grid scan of the rebar position. Profile scan of the rebar position.
Work Environment Condition: No strong alternating electromagnetic field. No corrosive gas in the air. Avoid larger vibration and impact. Avoid the LCD Panel contact with sunlight directly.
Specification: Bar diameter application range (mm): F 6-50. Maximum permissible error of Bar diameter: < + 1. Cover thickness measuring range: The first measuring range(mm): 6-90, The second measuring range (mm): 7-180. The maximum error of cover thickness: The first measuring range (mm): 6-59 < + 1, 60-69 < + 2, 70-90 < + 4. The second measuring range (mm): 7-79 < + 1, 80-119 < + 2, 120-180 < + 4.
Product Usage: Testing concrete cover thickness. Test concrete member internal reinforcement position, rebar spacing, reinforcement position distribution. Estimation bar diameter. Detection of Cable and Plumbing pipe.
Features: Investigation depth could reach 180mm. Single comprehensive probe. No need to replace during test. Back-lit screen lets instrument can be normal used under the condition of insufficient light. Machine software is complete. The report could be printed automatically connecting with computer. Grid scan of the rebar position. Profile scan of the rebar position.
Work Environment Condition: No strong alternating electromagnetic field. No corrosive gas in the air. Avoid larger vibration and impact. Avoid the LCD Panel contact with sunlight directly.
Related products
-
Material Testing Instruments
Constant Pressure LM17127 : SELF COMPENSATING CONSTANT PRESSURE SYSTEM
-
Material Testing Instruments
CONSOLIDATION TEST APPARATUS LM17221 THREE GANG
-
Material Testing Instruments
COMPACTION TEST APPARATUS : LM17331
-
Material Testing Instruments
CALIFORNIA BEARING RATIO LM1720601 : DIGITAL READOUT KIT FOR CBR
Sign up newsletter
Business is the activity of making one living or making money by producing or buying and selling products. Simply put it is any activity or enterprise entered into for profit.
By signing up agree our Terms & Services.
Reviews
There are no reviews yet.